Devo

Details

Protocol Number: 7 Autobind: No Channel Re-mapping: Yes Extended Limits: Yes Failsafe Support: Yes Receiver Match: Yes Telemetry: No Option Value: N/A

Notes

Serial Mode Binding

  • With the TX off, put the binding plug in and power on the RX (RX LED slow blink), then power it down and remove the binding plug. Receiver should now be in autobind mode.

  • Turn on the TX, set protocol = Devo with option=0, turn off the TX (TX is now in autobind mode).

  • Turn on RX (RX LED fast blink).

  • Turn on TX (RX LED solid, TX LED fast blink).

  • Wait for bind on the TX to complete (TX LED solid).

  • Make sure to set a uniq RX_Num value for model match.

  • Change option to 1 to use the global ID.

  • Do not touch option/RX_Num anymore.

PPM Mode Binding

  • With the TX off, put the binding plug in and power on the RX (RX LED slow blink), then power it down and remove the binding plug. Receiver should now be in autobind mode.

  • Turn on RX (RX LED fast blink).

  • Turn the dial to the model number running protocol DEVO on the module.

  • Press the bind button and turn on the TX. TX is now in autobind mode.

  • Release bind button after 1 second: RX LED solid, TX LED fast blink.

  • Wait for bind on the TX to complete (TX LED solid).

  • Press the bind button for 1 second. TX/RX is now in fixed ID mode.

  • To verify that the TX is in fixed mode: power cycle the TX, the module LED should be solid ON (no blink).

  • Note: Autobind/fixed ID mode is linked to the RX_Num number. Which means that you can have multiple dial numbers set to the same protocol DEVO with different RX_Num and have different bind modes at the same time. It enables PPM users to get model match under DEVO.

Channel Assignment

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH10

CH11

CH12

A

E

T

R

CH5

CH6

CH7

CH8

CH9

CH10

CH11

CH12

Sub Protocols

0 - 8CH

1 - 10CH

2 - 12CH

3 - 6CH

4 - 7CH

Last updated